Cypress manual AutoStore or Power Up Recall, Parameter Description CY14B101K Unit Min Max

Models: CY14B101K

1 28
Download 28 pages 22.07 Kb
Page 19
Image 19

 

 

 

 

 

 

 

 

CY14B101K

 

 

 

 

 

 

 

 

 

AutoStore or Power Up RECALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

 

Description

 

 

CY14B101K

 

Unit

 

 

 

Min

 

Max

 

 

 

 

 

 

 

 

 

tHRECALL [18]

Power Up RECALL Duration

 

 

 

40

 

ms

tSTORE [19, 20]

STORE Cycle Duration

Commercial

 

 

12.5

 

ms

 

 

 

 

Industrial

 

 

15

 

ms

 

 

 

 

 

 

 

 

VSWITCH

Low Voltage Trigger Level

 

 

 

2.65

 

V

tVCCRISE

VCC Rise Time

 

150

 

 

 

μs

Figure 12. AutoStore/Power Up RECALL

 

STORE occurs only

No STORE occurs

VCC

if a SRAM write

without atleast one

has happened

SRAM write

VSWITCH

 

tVCCRISE

 

AutoStore

tSTORE

tSTORE

POWER-UP RECALL

tHRECALL

tHRECALL

Read & Write Inhibited

Notes

18.tHRECALL starts from the time VCC rises above VSWITCH.

19.If an SRAM Write does not taken place since the last nonvolatile cycle, no STORE takes place.

20.Industrial Grade Devices require 15 ms Max.

Document Number: 001-06401 Rev. *I

Page 19 of 28

[+] Feedback

Page 19
Image 19
Cypress manual AutoStore or Power Up Recall, Parameter Description CY14B101K Unit Min Max