CY7C1161V18, CY7C1176V18

CY7C1163V18, CY7C1165V18

TAP AC Switching Characteristics

The Tap AC Switching Characteristics over the operating range follows.[16, 17]

Parameter

Description

Min

Max

Unit

tTCYC

TCK Clock Cycle Time

50

 

ns

tTF

TCK Clock Frequency

 

20

MHz

tTH

TCK Clock HIGH

20

 

ns

tTL

TCK Clock LOW

20

 

ns

Setup Times

 

 

 

 

tTMSS

TMS Setup to TCK Clock Rise

5

 

ns

tTDIS

TDI Setup to TCK Clock Rise

5

 

ns

tCS

Capture Setup to TCK Rise

5

 

ns

Hold Times

 

 

 

 

 

 

 

 

 

tTMSH

TMS Hold after TCK Clock Rise

5

 

ns

tTDIH

TDI Hold after Clock Rise

5

 

ns

tCH

Capture Hold after Clock Rise

5

 

ns

Output Times

 

 

 

 

 

 

 

 

 

tTDOV

TCK Clock LOW to TDO Valid

 

10

ns

tTDOX

TCK Clock LOW to TDO Invalid

0

 

ns

TAP Timing and Test Conditions

The Tap Timing and Test Conditions for the CY7C1161V18, CY7C1176V18, CY7C1163V18, and CY7C1165V18 follows.[17]

 

 

 

0.9V

 

 

 

 

 

 

 

 

50Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TDO

 

 

 

 

 

 

 

 

Z0

= 50Ω

 

 

 

 

 

CL = 20 pF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(a) GND

Test Clock

TCK

tTMSS

0V

tTH

ALL INPUT PULSES

1.8V

0.9V

tTL

tTMSH tTCYC

Test Mode Select

TMS

Test Data In

TDI

Test Data Out

TDO

tTDIS

tTDIH

 

tTDOV

 

 

 

 

 

t

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TDOX

Notes

16.tCS and tCH refer to the setup and hold time requirements of latching data from the boundary scan register.

17.Test conditions are specified using the load in TAP AC test conditions. tR/tF = 1 ns.

Document Number: 001-06582 Rev. *D

Page 17 of 29

[+] Feedback

Page 17
Image 17
Cypress CY7C1176V18, CY7C1165V18, CY7C1163V18, CY7C1161V18 TAP AC Switching Characteristics, TAP Timing and Test Conditions