CY7C1470BV25

CY7C1472BV25, CY7C1474BV25

TAP AC Switching Characteristics

Over the Operating Range [9, 10]

Parameter

Description

Min

Max

Unit

Clock

 

 

 

 

 

 

 

 

 

tTCYC

TCK Clock Cycle Time

50

 

ns

tTF

TCK Clock Frequency

 

20

MHz

tTH

TCK Clock HIGH time

20

 

ns

tTL

TCK Clock LOW time

20

 

ns

Output Times

 

 

 

 

tTDOV

TCK Clock LOW to TDO Valid

 

10

ns

tTDOX

TCK Clock LOW to TDO Invalid

0

 

ns

Setup Times

 

 

 

 

tTMSS

TMS Setup to TCK Clock Rise

5

 

ns

tTDIS

TDI Setup to TCK Clock Rise

5

 

ns

tCS

Capture Setup to TCK Rise

5

 

ns

Hold Times

 

 

 

 

 

 

 

 

 

tTMSH

TMS Hold after TCK Clock Rise

5

 

ns

tTDIH

TDI Hold after Clock Rise

5

 

ns

tCH

Capture Hold after Clock Rise

5

 

ns

Notes

9.tCS and tCH refer to the setup and hold time requirements of latching data from the boundary scan register.

10.Test conditions are specified using the load in TAP AC Test Conditions. tR/tF = 1 ns.

Document #: 001-15032 Rev. *D

Page 15 of 29

[+] Feedback

Page 15
Image 15
Cypress CY7C1474BV25, CY7C1472BV25 TAP AC Switching Characteristics, Parameter Description Min Max Unit Clock, Hold Times