CY7C1470BV25 CY7C1472BV25, CY7C1474BV25

possible to capture all other signals and simply ignore the value of the CLK captured in the boundary scan register.

After the data is captured, it is possible to shift out the data by putting the TAP into the Shift-DR state. This places the boundary scan register between the TDI and TDO balls.

Note that since the PRELOAD part of the command is not imple- mented, putting the TAP to the Update-DR state while performing a SAMPLE/PRELOAD instruction has the same effect as the Pause-DR command.

Figure 4. TAP Timing

BYPASS

When the BYPASS instruction is loaded in the instruction register and the TAP is placed in a Shift-DR state, the bypass register is placed between the TDI and TDO balls. The advantage of the BYPASS instruction is that it shortens the boundary scan path when multiple devices are connected together on a board.

Reserved

These instructions are not implemented but are reserved for future use. Do not use these instructions.

1

 

2

 

 

 

 

 

 

Test Clock

 

 

 

 

 

 

 

(TCK )

 

 

tTH

 

 

 

 

 

 

 

 

 

 

 

tTM SS

 

tTM SH

 

 

 

 

 

 

 

 

 

Test M ode Select (TM S)

tTDIS tTDIH

Test Data-In (TDI)

Test Data-Out (TDO)

3

4

5

6

tTL

tCY C

 

 

tTDOV

tTDOX

DON’T CA RE

UNDEFINED