13.Troubleshooting Problems and Odd Installation Problems

Listed below are some of the common problems found with installation and operation of the A/S-4 unit. Find the problem you are experiencing and try the remedies listed to fix the problem.

PROBLEM

SYMPTOM

POSSIBLE REMEDIES

 

 

 

 

 

 

1. No Power

Power light on front of

a. check wall power out-let for proper

 

A/S-4 is OFF

operation.

 

 

b. Check to make sure the power

 

 

transformer for the A/S-4 is

 

 

plugged into the wall and into the

 

 

unit all the way.

 

 

 

2. No power up

TCTS light is off,on

a. A/S-4 Switches SW2, SW3

message

front oF A/S-4

and SW6 for terminal port

 

 

are not set correctly, refer to

 

 

Section 4 in manual

 

 

b. Terminal device does not supply

 

 

DTR (if modem device is hooked to

 

 

terminal port, it does not supply DSR).

 

 

Turn on SW6/4 so A/S-4 unit will

 

 

supply DTR (if modem device turn

 

 

on SW6/5 so A/S-4 unit will supply

 

 

DSR).

 

 

 

 

TCTS light is on and

a. Speed detect option is on,

 

TTX light does not

type “S” to get power up message.

 

blink when power is

b. Typing “S” for speed option still

 

applied to the A/S-4

does not give power up message.

 

unit

Baud rate cannot be matched by speed

 

 

detect option so set up switches on

 

 

A/S-4 to match terminal baud rate

 

 

(refer to Section 4.1).

 

 

 