CHAPTER 4: Switches

SW6/ 7

8

9

10

BAUD RATE

 

 

 

 

 

 

 

 

 

 

 

ON

ON

ON

ON

50

 

 

 

ON

ON

ON

OFF

75

 

 

 

ON

ON

OFF

ON

110

 

 

 

ON

ON

OFF

OFF

134.5

 

 

 

 

 

 

 

 

 

 

 

ON

OFF

ON

ON

150

 

 

 

ON

OFF

ON

OFF

300

 

 

 

ON

OFF

OFF

ON

600

 

 

 

ON

OFF

OFF

OFF

1200

 

 

 

 

 

 

 

 

 

 

 

OFF

ON

ON

ON

1800

NOTE: Baud Rate

 

 

OFF

ON

ON

OFF

2000

selection has no

 

 

OFF

ON

OFF

ON

2400

effect if Terminal

 

 

OFF

ON

OFF

OFF

3600

Speed Detect is

 

 

 

 

 

 

 

selected.

 

 

OFF

OFF

ON

ON

4800

 

 

 

OFF

OFF

ON

OFF

7200

 

 

 

OFF

OFF

OFF

ON

9600

 

 

 

OFF

OFF

OFF

OFF

19.2K

 

 

 

 

 

 

 

 

 

4.3 Modem Switches

Modem port switches for Female DB25 Modem Connector

Switch Bank S4, Switch:

1-On connects pin 4 of connector to A/S-4’s input of

CLEAR-TO-SEND

2-On connects pin 5 of connector to A/S-4’s input of CLEAR-TO-SEND, for attaching DCE devices

3-On connects pins 25 on both terminal and modem connectors to +5 volts DC.

4-On connects pin 19 of connector to A/S-4’s input of CLEAR-TO-SEND, for printers with busy on pin 19

5-On connects pin 20 of the connector to A/S-4’s input of CLEAR-TO-SEND, for devices with busy on pin 20

6-On connects pin 6 of connector to A/S-4’s input of

CARRIER DETECT

7-On connects pin 8 of connector to A/S-4’s input of

CARRIER DETECT

8-On connects pin 15 of connector to A/S-4’s input of Transmit Clock for synchronous operation

15

Page 16
Image 16
Black Box A/S-4 manual Modem Switches, Clear-To-Send