Black Box A/S-4 manual Request-To-Send

Models: A/S-4

1 88
Download 88 pages 61.23 Kb
Page 17
Image 17

PROTOCOL CONVERTER MODEL A/S-4

Switch Bank S5, Switch:

1-On connects pin 2 of connector to A/S-4’s output of Transmit Data, for attaching DCE devices

2-On connects pin 3 of connector to A/S-4’s output of Transmit Data, for attaching DTE devices

3-On connects pin 2 of connector to A/S-4’s input of Receive Data, for attaching DTE devices

4-On connects pin 3 of connector to A/S-4’s input of Receive Data, for attaching DCE devices

5-On connects pin 4 of connector to A/S-4’s output of REQUEST-TO-SEND, for attaching DCE devices

6-On connects pin 5 of connector to A/S-4’s output of

REQUEST-TO-SEND

7-On connects A/S-4’s REQUEST-TO-SEND to A/S-4’s CLEAR-TO-SEND so that no external signals are needed. Used for Burroughs TDI and non-hardware throttle devices

8-On connects pins 4 and 5 of connector so external devices throttle itself

Switch Bank S7, Switch:

1-On supplies internal clocking for A/S-4’s input of Transmit Clock

2-On connects pin 17 of connector to A/S-4’s input of Receive Clock, for synchronous operation

3-On supplies internal clocking for A/S-4’s input of Receive Clock 4-On connects pin 20 of connector to A/S-4’s output of

DATA-TERMINAL-READY, for attaching DCE devices

5-On connects pin 20 of connector to A/S-4’s input of

CARRIER DETECT

6-On supplies 1X clock for internal modem port use 7, 8, 9 and 10 reserved

Switch Bank S6, Switch:

6-On supplies 16X clock for internal modem port use, for synchronization of synchronous data over async modems

16

Page 17
Image 17
Black Box A/S-4 manual Request-To-Send