PROTOCOL CONVERTER MODEL A/S-4

2.Modem connected to host but LU inactive; if the LU is inactive the A/S-4 will display “WAITING FOR LU TO COME ACTIVE”. The LU should come active after a few seconds of this message appearing on the VDU. If the LU does not come active, then one of the following problems may exist:

A.Host is not polling PU (Physical Unit) Solution: Have a network operator activate the PU and maybe the line also.

B.PU address (or station address) is incorrect Solution: Return to A/S-4 menus and change PU address.

C.LU address is incorrect Solution: Return to A/S-4 menus and change LU address.

After the LU comes Active, the A/S-4 will proceed to the following state. Refer to Section 13.0 on Trouble Shooting if the LU will not activate for more information.

NOTE

In states 1 and 2 typing any key will return A/S-4 to it’s Main Menu

3.Application running:

Interactive - The A/S-4 will refresh the VDU’s screen with the last screen received from the host (which could be blank). Operation will then function as a 3278 CRT.

Batch - The A/S-4 will display the status of the LU on the status line but no previous data from the system will be displayed on the VDU. Operation will then function as a 3770 work station.