PROTOCOL CONVERTER MODEL A/S-4

Switch Bank S3, Switch:

1-On connects pin 2 of connector to A/S-4’s output of Transmit Data, for attaching DCE devices

2-On connects pin 3 of connector to A/S-4’s output of Transmit Data, for attaching DTE devices

3-On connects pin 2 of connector to A/S-4’s input of Receive Data, for attaching DTE devices

4-On connects pin 3 of connector to A/S-4’s input of Receive Data, for attaching DCE devices

5-On connects pin 4 of connector to A/S-4’s output of REQUEST-TO-SEND, for attaching DCE devices

6-On connects pin 5 of connector to A/S-4’s output of

REQUEST-TO-SEND

7-On connects A/S-4’s REQUEST-TO-SEND to A/S-4’s CLEAR-TO-SEND so that no external signals are needed. Used for Burroughs TDI and non-hardware throttle devices

8-On connects pins 4 and 5 of connector so external devices throttle itself

Switch Bank S6, Switch:

1-On supplies internal clocking for A/S-4’s input of Transmit Clock

2-On connects pin 17 of connector to A/S-4’s input of Receive Clock, for synchronous operation

3-On supplies internal clocking for A/S-4’s input of Receive Clock

4-On connects pin 20 of connector to A/S-4’s output of DATA-TERMINAL-READY, for attaching DCE devices

5-On connects pin 20 of connector to A/S-4’s input of

CARRIER DETECT

6-For modem port, see Modem Switches

7, 8, 9 and 10 - Set up terminal baud rate, if speed detection is turned off.

12

Page 13
Image 13
Black Box A/S-4 manual Request-To-Send