8.4 Batch Default Options

The A/S-4 has the capability of loading all it’s Batch options from the VDU (computer) without going through any menus. This is done by receiving the shift out (X’0E;) character followed by the options selected in hexadecimal form. The VDU and A/S-4 must be set to receive and transmit an 8-data bit word with no parity, so all 8 bits of the hexadecimal characters are received. Once all the new Batch default options are loaded, the A/S-4 is then automatically set to run in the Batch 3776/77 mode. Below is the Batch options with its bit location.

BYTE

DEFAULT

*** SDLC (MODEM) PORT OPTIONS ***

 

 

1

17

BIT 7 -

 

 

 

6

-

 

 

 

5

& 4 - 00=ASYNC, 01=SYNC

 

 

3 THRU 0 = BAUD RATE

 

 

0101 = 300

1100 = 4800

 

 

0110 = 600

1110 = 9600

 

 

0111 = 1200 1111 = 19.2K

 

 

1010 = 2400

 

2

0C

BIT 5 & 4 - STOP BITS: 00=SYNC, 01=1, 10=1.5, 11=2

 

 

3

& 2 - WORD LENGTH: 10=7, 11=8

 

 

1

& 0 - PARITY: X0=NONE, 01=ODD, 11=EVEN

3

00

BIT 6 & 5 - XON/OFF: 00=OFF, 01=FROM VDU, 10=TO VDU,

 

 

 

 

11=BOTH

 

 

1

& 0 - CHAR CODE: 00=EBCDIC, 01=ASCII

4

F7

SDLC PU ADDRESS

5

80

CUSTOMER OPTIONS A

6

02

CUSTOMER OPTIONS B

7

01

PROTOCOL, 00=3274/76, 01=3776/66

8

30

SDLC 3770 XID

90F

10FF

 

 

*** ASYNC (TERMINAL) PORT OPTIONS ***

 

 

*** INBOUND (VDU) LU ***

11

07

ASYNC BAUD RATE (1200 BAUD) SEE BYTE 1

12

0C

WORD LENGTH: 8 - DATA BITS, NO PARITY SEE

 

 

BYTE 2

13

01

CHAR OPTION: XON/OFF=OFF, ASCII CHARACTERS