PROTOCOL CONVERTER MODEL A/S-4
PROGRAMMABLE PRINTER OPTIONS
Print data received from the host or printed by a local print function will be formatted by the values set in the Printer Options menu (e.g. Column Width, Lines Per Page, Single spacing). The
a.Set Horizontal Format (SHF) command defines the maximum presentation position (MPP), the left margin (LM), right margin (RM) and up to six horizontal tab stops for a page of print. At the present time, the only value passed on to the printer by the
The following is an example of setting the printer for a 80 column page:
ESC, F, 8, 0 - OKI Microline 83A command to set 80 column page
Printer Options Menu settings:
b.Set Vertical Format (SVF) command defines the maximum presentation line (MPL), top margin (TM), bottom margin (BM) and up to six vertical tab stops for a page of print. At the present time the only value passed on to the printer by the
The following is an example of setting the printers page length of 11 inches.
ESC,[,7920r - GENICOM 3000 command to set 11 inch page
Printer Options Menu settings:
c.Set Line Density (SLD) specifies the (LPI) distance to be moved for a single line (vertical spacing), as in NL or LF. When the SLD is received the new value overrides any default lines per inch (LPI) value set by the printer options menu and the new LPI value is then sent to the printer. If the Start
48