CY7C64215

Table 5. Units of Measure (continued)

 

 

 

 

 

 

Symbol

Unit of Measure

Symbol

Unit of Measure

μV

microvolts

s

sigma: one standard deviation

μVrms

microvolts root-mean-square

V

volts

Absolute Maximum Ratings

Table 6. Absolute Maximum Ratings

Parameter

Description

Min

Typ

Max

Unit

Notes

 

TSTG

Storage Temperature

–55

+100

°C

Higher storage temperatures

 

 

 

 

 

 

 

reduces data retention time.

 

TA

Ambient Temperature with Power Applied

0

+70

°C

 

 

Vdd

Supply Voltage on Vdd Relative to Vss

–0.5

+6.0

V

 

 

VIO

DC Input Voltage

Vss – 0.5

Vdd + 0.5

V

 

 

VIO2

DC Voltage Applied to Tri-state

Vss – 0.5

Vdd + 0.5

V

 

 

IMIO

Maximum Current into any Port Pin

–25

+50

mA

 

 

IMAIO

Maximum Current into any Port Pin

–50

+50

mA

 

 

 

Configured as Analog Driver

 

 

 

 

 

 

ESD

Electro Static Discharge Voltage

2000

V

Human Body Model ESD.

 

LU

Latch Up Current

200

mA

 

 

Operating Temperature

 

 

 

 

 

 

Table 7. Operating Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Description

Min

Typ

Max

Unit

Notes

 

TA

Ambient Temperature

0

+70

°C

 

 

TJ

Junction Temperature

0

+88

°C

The temperature rise from

 

 

 

 

 

 

 

ambient to junction is

 

 

 

 

 

 

 

package specific. See

 

 

 

 

 

 

 

“Thermal Impedance” on

 

 

 

 

 

 

 

page 28. The user must limit

 

 

 

 

 

 

 

the power consumption to

 

 

 

 

 

 

 

comply with this

 

 

 

 

 

 

 

requirement.

 

Document 38-08036 Rev. *C

Page 14 of 30

[+] Feedback

Page 14
Image 14
Cypress CY7C64215 manual Absolute Maximum Ratings, Operating Temperature