CY7C64215

AC Digital Block Specifications

The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V and 0°C < TA < 70°C, or 3.0V to 3.6V and 0°C < TA < 70°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and are for design guidance only.

Table 21. AC Digital Block Specifications

Function

Description

Min

Typ

Max

Unit

Notes

Timer

Capture Pulse Width

50[11]

ns

 

 

Maximum Frequency, No Capture

49.92

MHz

4.75V < Vdd < 5.25V.

 

Maximum Frequency, With Capture

25.92

MHz

 

Counter

Enable Pulse Width

50[11]

ns

 

 

Maximum Frequency, No Enable Input

49.92

MHz

4.75V < Vdd < 5.25V.

 

Maximum Frequency, Enable Input

25.92

MHz

 

Dead

Kill Pulse Width:

 

 

 

 

 

Band

 

 

 

 

 

 

Asynchronous Restart Mode

20

ns

 

 

 

 

Synchronous Restart Mode

50[11]

ns

 

 

Disable Mode

50[12]

ns

 

 

Maximum Frequency

49.92

MHz

4.75V < Vdd < 5.25V.

CRCPRS

Maximum Input Clock Frequency

49.92

MHz

4.75V < Vdd < 5.25V.

(PRS

 

 

 

 

 

 

Mode)

 

 

 

 

 

 

CRCPRS

Maximum Input Clock Frequency

24.6

MHz

 

(CRC

 

 

 

 

 

 

Mode)

 

 

 

 

 

 

SPIM

Maximum Input Clock Frequency

8.2

MHz

Maximum data rate at 4.1 MHz due to

 

 

 

 

 

 

2 x over clocking.

SPIS

Maximum Input Clock Frequency

4.1

MHz

 

 

Width of SS_ Negated Between Trans-

50[11]

ns

 

 

missions

 

 

 

 

 

Trans-

Maximum Input Clock Frequency

24.6

MHz

Maximum data rate at 3.08 MHz due to

mitter

 

 

 

 

 

8 x over clocking.

Receiver

Maximum Input Clock Frequency

24.6

MHz

Maximum data rate at 3.08 MHz due to

 

 

 

 

 

 

8 x over clocking.

AC External Clock Specifications

The following tables list guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V and 0°C < TA < 70°C, or 3.0V to 3.6V and 0°C < TA < 70°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and are for design guidance only.

Table 22. AC External Clock Specifications

Parameter

Description

Min

Typ

Max

Unit

Notes

FOSCEXT

Frequency for USB Applications

23.94

24

24.06

MHz

 

Duty Cycle

47

50

53

%

 

Power - up to IMO Switch

150

μs

 

Note

11. 50 ns minimum input pulse width is based on the input synchronizers running at 24 MHz (42 ns nominal period).

Document 38-08036 Rev. *C

Page 23 of 30

[+] Feedback

Page 23
Image 23
Cypress CY7C64215 manual AC Digital Block Specifications, AC External Clock Specifications