VS-1200 Data Acccess Switch

SOLUTION: The VS-1210BT/SFP solves all goals by accepting the input from the two SPAN ports along with the output from the TAP, aggregating and replicating the traffic to multiple ports and ports 9 and 10 provide small form pluggables that allow either fiber or copper connectivity.

CONFIGURATION: The IP address (default 192.168.1.1), Subnet Mask and Default Gateway is set during the 'Initial Configuration' for your Local Area Network settings and will not be covered in this section, see the 'IP Address Configuration with HyperTerminal 28 ' section for those steps. Use the syntax below in the Command Line Interface (CLI) to setup Tap and Any-to-Any ports (syntax is shown with either user > or Superuser # prompts):

For configuration, open HyperTerminal on your Management PC using the VS-1210BT/SFP SERIAL DB9 port. Settings are found in the 'Initial Configuration', 'SERIAL Port Configuration (DB9)', 'HyperTerminal 26 ' section.

Press twice Enter key and Enter key. Enter Username (default: Administrator) and Enter key.

Enter Password (default: admin) and Enter key. Default prompt is the > symbol. Enter superuser

mode, type su and Enter key. Enter Password (default: password) and Enter key. Default prompt is the # symbol. Use the following syntax to set the input/output for Any-to-Any ports as well as the output for Tap ports.

The VS-1200 Series factory default for all Any-to-Any ports is off.

Ensure there are no previous settings present, go through Ports 1-10 and set them to OFF as shown:

#SET PORT MONITOR 1 OFF

#SET PORT MONITOR 2 OFF

#SET PORT MONITOR 3 OFF

#SET PORT MONITOR 4 OFF

#SET PORT MONITOR 5 OFF

#SET PORT MONITOR 6 OFF

#SET PORT MONITOR 7 OFF

#SET PORT MONITOR 8 OFF

#SET PORT MONITOR 9 OFF

#SET PORT MONITOR 10 OFF