52

VS-1200 Data Acccess Switch

IMPORTANT: Fiber taps are not capable and CAN NOT auto-negotiate link with the VS- 1210SFP ports and MUST BE be hard set to 1,000 Mbs and full-duplex.

Port 1, 2, 3, and 4's is set to 1,000 Mbs and full-duplex with this syntax:

# SET PORT SPEED 1,2,3,4 1000FULL

Now you can begin setting the ports as to which port inputs the data and which ports aggregate and/or output the data.

Port 5 is set as output for Port 1 and 3’s input which is set with this syntax:

# SET PORT MONITOR 5 FROM 1,3

Port 6 is set as output for Port 1 and 3’s input which is set with this syntax:

# SET PORT MONITOR 6 FROM 1,3

Port 7 is set as output for Port 2 and 4’s input which is set with this syntax:

# SET PORT MONITOR 7 FROM 2,4

Port 8 is set as output for Port 2 and 4’s input which is set with this syntax:

# SET PORT MONITOR 8 FROM 2,4

Port 9 is set as output for Port 1, 2, 3 and 4’s input which is set with this syntax:

# SET PORT MONITOR 9 FROM 1,2,3,4

Port 10 is set as output for Ports 4’s input which is set with this syntax:

# SET PORT MONITOR 10 FROM 4

CONCLUSION: The VS-1210BT/SFP provides the ability to aggregate data streams from TAPs. Aggregating streams together improves overall visibility for the tools and permits specific departmental devices to only see the traffic they need. The VS-1210SFP allows many devices to share a single output. The VS-1210SFP Small Form Pluggable capacity, allows users to send data across multimode, single-mode fiber or copper.