Datalogic Scanning 1000I manual Code 39 Length 1, Length 2 Programming Instructions, Quiet Zones

Models: 1000I

1 176
Download 176 pages 51.63 Kb
Page 106
Image 106

Symbologies

Code 39 Length 1, Length 2 Programming Instructions

1.Scan the START/END barcode.

2.Scan either the Set Length 1 or Set Length 2 barcode.

3.Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent- ing the length in decimal notation.

For Code 39 barcodes, all check, data and full ASCII shift characters are included in the length calculations. Start/Stop characters are not included.

NOTE

4. Scan the START/END barcode.

START / END

PROGRAMMING BARCODES

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 003

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 050

Quiet Zones

This feature enables/disables the requirement that quiet zones must be present for Code 39 bar- codes.

START / END

PROGRAMMING BARCODES

Don’t require Quiet Zones

DEFAULT

Require Quiet Zones

³0

0 1

5-30

Magellan® 1000i

Page 106
Image 106