Datalogic Scanning 1000I manual MSI/Plessey Length 1, Length 2 Programming Instructions

Models: 1000I

1 176
Download 176 pages 51.63 Kb
Page 135
Image 135

MSI/Plessey

MSI/Plessey — continued

MSI/Plessey Length 1, Length 2 Programming Instructions

1.Scan the START barcode.

2.Scan either the Set Length 1 or Set Length 2 barcode.

3.Turn to Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent- ing the length in decimal notation.

For MSI/Plessey barcodes, all check and data char- acters are included in the length calculations.

NOTE

4. Scan the END barcode.

START / END

PROGRAMMING BARCODES

Set Length 1

DEFAULT SETTING FOR THIS FEATURE: 004

Set Length 2

DEFAULT SETTING FOR THIS FEATURE: 016