Interface Related Features

Wand Emulation

Supported Symbologies

The Wand Emulation interface will transmit barcode data as a wand device would. This inter- face will transmit the following barcode symbologies:

UPC/EAN

UPC/EAN with addons

Code 39

Full ASCII Code 39

Interleaved 2 of 5

Codabar

Code 128

Pharmacode 39 is transmitted as Code 39. All other barcode symbology types read by the scan- ner will be transmitted as Code 128.

Wand Emulation Barcode Format

The following format settings are required for the wand emulation interface. These settings have been pre-configured at the factory for Wand Emulation scanners.

UPC-A barcodes must include all 12 digits.

UPC-E barcodes must contain 8 digits, including a system digit, 6 data digits, and the check digit.

EAN-13 barcodes must have all 13 digits.

EAN-8 barcodes must include all 8 digits.

Code 39, Code 39 Full ASCII, and Pharmacode 39 barcodes must NOT contain start / stop characters.

Codabar barcodes must include the start / stop characters, presented in the ABCD format.

Interleaved 2 of 5 barcodes must have an even number of digits.

3-26