Datalogic Scanning 1000I manual Label Gone Timeout, Productivity Index Reporting PIR

Models: 1000I

1 176
Download 176 pages 51.63 Kb
Page 15
Image 15

Label Gone Timeout

Label Gone Timeout

This feature sets the time after the last label segment is seen before the scanner prepares for a new label.

START / END

PROGRAMMING BARCODES

Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To configure this feature, scan the “START/END” barcode above to place the unit in Programming Mode, then the “Set Label Gone Tim- eout,” followed by the three digits (zero padded) from the Alphanumeric table in Appendix C, Alpha-Numeric Pad representing the desired time value. Exit programming mode by scanning the “START/END” barcode again.

DEFAULT SETTING FOR THIS FEATURE: 320 milliseconds (032)

Set Label Gone Timeout

Productivity Index Reporting (PIR)

When PIR is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer, indicating how easy the label was to read.

This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced

NOTE capability.

START / END

PROGRAMMING BARCODES

Disable

DEFAULT

Enable

Product Reference Guide

2-3

Page 15
Image 15