2D Symbologies
PDF 417 — continued
Length Control
Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a barcode if the label length matches one of the configurable fixed lengths.
Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a barcode if the label length falls in the range of the configurable minimum and maxi- mum length.
Configuring Fixed Length Decoding:
1.Scan the START barcode.
2.Scan the Fixed Length Decoding barcode.
3.Scan the END barcode.
4.Set Length 1 to the first fixed length by following the Length 1, Length 2 Programming Instructions below.
5.Set Length 2 to the second fixed length (or to ‘00’ if there is only one fixed length) by fol- lowing the PDF 417 Length 1, Length 2 Programming Instructions below.
Configuring Variable Length Decoding:
1.Scan the START barcode.
2.Scan the Variable Length Decoding barcode.
3.Scan the END barcode.
4.Set Length 1 to the minimum length by following the PDF 417 Length 1, Length 2 Pro-
gramming Instructions below.
5. Set Length 2 to the maximum length by following the PDF 417 Length 1, Length 2 Pro- below.
START / END
PROGRAMMING BARCODES
Variable Length Decoding
Fixed Length Decoding
Product Reference Guide |