2.3 JUNCTION BOX INSTALLATION

The junction box provides a passive connection between your scanner and the outside world in a fast and practical way. It represents an alternative to the 25-pin connector models. Figure 2.3 shows the basic layout of DS4300 using the junction box.

Scanner

Junction Box

cable

 

DS4300

System cables

Figure 2.3 - Scanner using junction box

For junction box connections, the scanner has a cable that terminates in a 24-pin connector that plugs into the junction box. The system cables pass through 6 glands in the side of the junction box and the individual wires connect to spring clamp terminal blocks inside which provide access to all scanner signals.

2.3.1 Junction Box Mounting

The diagram below shows the dimensions of the junction box and its relative mounting holes.

mm

in

Figure 2.4 - Junction box dimensions