Datalogic Scanning DS4300 manual Ext Trig+

Models: DS4300

1 53
Download 53 pages 9.34 Kb
Page 32
Image 32

DATALOGIC

 

 

 

DS4300

The pinouts are indicated below:

 

 

 

 

 

 

 

 

 

Pin

Name

Function

 

 

 

 

 

 

 

18

EXT TRIG+

external trigger +

 

 

19

EXT TRIG-

external trigger -

 

 

6

IN1+

input 1

+

 

 

10

IN1-

input 1

-

 

 

14

IN2+

input 2

+

 

 

15

IN2-

input 2

-

 

The EXT TRIG inputs are used in the ON-Line Operating mode and tells the scanner to scan for a code. The active state of this input is selected in software. Refer to the WinHost Help On Line. The yellow led, (Figure A/B,

5), is on when the External Trigger signals the active reading phase.

These inputs are optocoupled and can be driven by both an NPN or PNP type command. The connections are indicated in the following diagrams:

DS4300

+ 5V

Vext

30 Vdc max.

18/6/14 +

19/10/15 -

USER INTERFACE

V

Signal

Figure 2.20 - Input NPN command using external power

DS4300

+ 5V

9VS

18/6/14 +

19/10/15 -

25GND

USER INTERFACE

V

Signal

Ground

Figure 2.21 - Input NPN command using DS4300 power

Installation - 2.17