NOTE

The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure.

The termination resistors of the RS485 bus must not be installed.

2.6.5 Multiplexer

Each scanner is connected to an MX4000 with the RS485 half duplex mode on the main interface.

 

1

0

1

31

 

 

MX4000

 

 

 

 

 

2

 

2

2

Host

 

3

3

3

1 RS485 HD Main interface

2Auxiliary interface (Local Echo)

3External Trigger (for On-Line mode)

Figure 2.32 - Multiplexer layout

The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure.

When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.