Image 53

DS4300DATALOGIC

SOFTWARE FEATURES

READABLE CODE SYMBOLOGIES

EAN/UPC

Code 93

2/5 Interleaved

Code 128

Code 39

EAN 128

Codabar

Pharmacode

 

 

CODE SELECTION

up to six codes during one reading phase

 

 

DECODING SAFETY

can enable multiple good reads of same code

 

 

HEADERS AND TERMINATORS

up to four headers and four terminators

 

 

OPERATING MODES

ON LINE, AUTOMATIC, SERIAL ON LINE, TEST

 

 

CONFIGURATION MODES

through menus using WinHost utility

 

 

 

 

 

receiving commands from one of the serial

 

 

ports (HOST MODE)

 

 

PARAMETER STORAGE

Non-volatile internal memory

 

 

 

ENVIRONMENTAL FEATURES

 

 

 

 

Operating temperature (Note 3)

0 to 40 ° C (32 to 104 °F)

Storage temperature

-20

to 70 ° C (-4 to 158 °F)

Humidity max.

90% non condensing

Vibration resistance

IEC 68-2-6 test FC 1.5 mm;

 

 

10 to 55 Hz; 2 hours on each axis

Shock resistance

IEC 68-2-27 test EA 30G;

 

 

11 ms; 3 shocks on each axis

Protection class

IP65

 

 

 

PHYSICAL FEATURES

 

 

Mechanical dimensions

101 x 83.5 x 42 mm (3.97 x 3.29 x 1.65 in.)

Weight

about 800 g. (28.2 oz.)

 

 

 

 

Note 1: The features given are typical at a 25 ° C ambient temperature (if not otherwise indicated).

Note 2: Further details given in paragraphs 3.3 and 3.4.

Note 3: If the reader is used in high temperature environments (over 35 ° C), use of the Beam shutter is advised (for details refer to the WinHost Help On Line).