Datalogic Scanning DS4300 manual MA Current Loop INT-24 Accessory Only, Clin

Models: DS4300

1 53
Download 53 pages 9.34 Kb
Page 30
Image 30

DATALOGIC

DS4300

20 mA Current Loop (INT-24 Accessory Only)

When the INT-24 accessory board is installed, the DS4300 is equipped with a 20 mA active current loop interface.

The following pins of the 25-pin connector are used for the connections:

Pin

Name

Function

 

 

 

4

CLOUT-

current loop output

5

CLIN-

current loop input

7

SGND Main

signal ground main interface

DS4300/DS4600

USER INTERFACE

+

 

I = 20 mA

 

4

C.L. OUT-

+

I = 20 mA

7SGND Main

5C.L. IN-

GND

MAX. 300 METERS

Figure 2.18 - 20 mA active C.L. connections

For 20 mA passive current loop interface connections, contact your local Datalogic representative.

Installation - 2.15

Page 30
Image 30
Datalogic Scanning DS4300 manual MA Current Loop INT-24 Accessory Only, Clin