Datalogic Scanning DS4300 manual Input PNP command using external power

Models: DS4300

1 53
Download 53 pages 9.34 Kb
Page 33
Image 33

DS4300

DS4300

+ 5V

DATALOGIC

Vext 30 Vdc max.

USER INTERFACE

 

 

V

18/6/14

+

Signal

 

19/10/15

-

Ground

 

 

Figure 2.22 - Input PNP command using external power

DS4300

+ 5V

9VS

18/6/14 +

19/10/15 -

25GND

USER INTERFACE

V

Signal

Figure 2.23 - Input PNP command using DS4300 power

The electrical features of the inputs are:

Maximum voltage = 30 Vdc

Maximum current = 25 mA.

An anti-disturbance hardware filter is implemented on the External Trigger input (< 5 milliseconds delay).

An additional 15 ms (typical) delay can be implemented through a dedicated software parameter (refer to WinHost Help On Line).

2.18- Installation