USING THE GRILL

LIGHTING INSTRUCTIONS

TO LIGHT THE GRILL BURNER:

Open the grill lid and/or remove the top grate cover from side burner (for 48BQR) before lighting. Turn all knobs to “OFF”. Turn the main gas supply on slowly. If you smell gas, shut off gas supply and call for service.

Push and hold the ignition button, turn the selected burner knob to “SEAR”. If burner does not light in 4 to 5 sec- onds, turn knob “OFF” and wait 5 minutes before trying again for any accumulated gas to dissipate.

Grill Match Lighting:

 

 

If the burner will not light after several attempts then the burner

 

 

can be match lit. If you’ve just attempted to light the burner with

 

 

the ignition, allow 5 minutes for any accumulated gas to dissipate.

 

 

Keep your face as far away from the grill as possible and hold and

 

 

pass a lit, paper book match over the hole located on the top left

 

 

for burner on the left, or the right hole for the right burner (Fig. 26

 

 

& Fig. 27). Push and turn the control knob which is centered on the

FIG. 26

FIG. 27

burner where the lit match is located, to “SEAR”. If the burner does

not light in 4 seconds, turn the knob off, wait 5 minutes and try again.

Once the left or right burner is lit, the adjacent burner can be lit by the cross-lighting method. For center burners to cross light, light the adjacent far left or right burner using the standard or match light procedure. Push and turn the control knob for the desired center burner to “SEAR”. The gas will be ignited by the adjacent burners flame. If the burner does not light in 4 seconds, turn knob off, wait 5 minutes and try again.

NOTE:

Improper lighting procedures can cause the LP tank flow control to activate, resulting in reduced heat output. If this is suspected, to reset flow control, shut off all burner controls and LP cylinder valve, wait 30 seconds, then turn LP cylinder valve on extremely slowly, wait five (5) seconds and push and hold the ignition button and turn burner valve on to “SEAR”.

TO LIGHT DUAL SIDE BURNERS (48BQR MODELS ONLY):

CAUTION!

The side burner cover may be hot if the grill burners are in operation.

WARNING

Failure to follow the steps in the order shown may cause the Flow Limiting Device to activate resulting in extremely low gas flow and improper operation.

1

OFF

All knobs must be in the OFF position before

 

 

 

opening LP tank valve.

 

SEAR

 

2

 

Attach regulator hose assembly to tank.

3

 

Now open the LP tank valve two (2) full

 

 

turns min.

Side Burners Lighting Instructions:

First remove the burner cover and any cooking utensils from the burner grate. Push and hold the ignition button, turn the control knob to the “HI” position until the burner is lit or 4 seconds pass. If the burner doesn’t ignite, wait 5 minutes for any accumulated gas to dissipate then try again. If the burner will not light after several attempts, check the trouble shooting instructions on page 31.

IGNITION

Control Knobs

Ignition

FIG. 28

Side Burners Match Lighting:

Hold a lit paper book match near the burner ports, turn the control knob counterclockwise to “HI”. Move your hand immediately once the burner is lit. Rotate the control knob to the desired setting.

Note:

If you are using propane gas, a slight pop or flash may occur at the burner ports a few seconds after the burner has been turned “off”. This “extinction pop” is normal for propane gas.

Cap

FIG. 29

Side burners:

Your side burner is equipped with burners typical of those used in restaurants. These burners are designed for maximum cleanability and controlability. The burner should never be operated if the cap is not in place (Fig. 29).

20

Page 22
Image 22
DCS 36/48BGB manual Using the Grill, Lighting Instructions, To Light the Grill Burner