Dell 5100MP owner manual Projector Response Message x00 Success

Models: 5100MP

1 378
Download 378 pages 23.56 Kb
Page 54
Image 54

w w w . d e l l . c o m s u p p o r t . d e l l . c o m

Address Code "10" ==> pt_OEM

Payload Size "05 00"==> From wMsgID to end

CRC "C6 FF" ==> If CRC value is "C6 (Low Byte) FF (High Byte)" MsgID "11 11"

MsgSize "01 00"==> From command to end. Command "01"==> "Power ON" command.

Projector Response Message Table: 0x00: Success

0x01: Invalid command (on the control command list but not valid. e.g. card reader command while no card reader plug-in)

0x02: Error command (includes CRC error and unknown commands).

0x03: System Status - Projector ON (Normal Mode).

NACK: System Status - Projector OFF (Standby Mode).

Note: When the projector is in the standby mode, no acknowledgement (NACK) response is sent by the projector.

Projector Response Lamp Hour: Byte0, Byte1, Byte2, Byte3 Byte0: 0x00 (Success)

Byte1: 0x2F (the header of lamp hour)

Byte2: LSB (Hex)

Byte3: MSB (Hex)

Ex: 800 (3x256+2x16=800) hours --> 0x00, 0x2F, 0x20, 0x03

Firmware version Response:

Firmware version: 4 Bytes ASCII Code: "V*.*"

V: Version

*: 0-9

Example: Version 1.5 --> "V1.5" --> 0x00, 0x30, 0x56, 0x31, 0x2E, 0x35 (Success,

header of firmware version, 4 Bytes ASCII Code: "V*.*")