1 FCoE Initialization Protocol

FIP logout

FIP logout operates as follows:

ENodes can log out from the Dell FCoE hardware using FIP. The Dell FCoE hardware in the fabric updates the MAC address, WWN, and PID mappings upon logout. The Dell FCoE hardware also handles scenarios of implicit logout where the ENode has left the fabric without explicitly logging out.

FIP logout (LOGO)—The Dell FCoE hardware accepts a FIP LOGO from the ENode. The FIP LOGO ACC should be sent to the ENode if the ENode MAC address matches the VN_port table on the Dell FCoE hardware. The LOGO is ignored (not rejected) if the ENode MAC address does not match. The ENode logout is updated in the VN_port table. FPMA is supported.

Implicit logout—With the ENode directly connected to a CEE port, if the port that the ENode is attached to goes offline, the Dell FCoE hardware implicitly logs out that ENode. ENode logout is updated in the VN_port table. The Dell FCoE hardware sends FCoE LOGO on behalf of the ENode.

FCoE login

The Dell FCoE hardware FCoE login operates as follows:

ENodes can log in to the Dell FCoE hardware using FCoE encapsulated, FC Extended Link Service (ELS) frames. FLOGI and FDISC are accepted. Dell FCoE hardware in the fabric maintains the MAC address to WWN/PID mappings per login. Class 2 FLOGI is not supported.

FCoE FLOGI—The Dell FCoE hardware accepts FCoE FLOGI from the ENode. FCoE FLOGI ACC is sent to the ENode if the FCMAP matches the VN_port table on the Dell FCoE hardware. Requests are ignored if the FCMAP does not match. The ENode login is added to the VN_port table.

FCoE FDISC—The Dell FCoE hardware accepts FCoE FDISC from the ENode. FCoE FDISC ACC is sent to the ENode if the FCMAP matches the VN_port table on the Dell FCoE hardware. The FCoE FDISC request is ignored if the FCMAP does not match. The ENode login is added to the VN_port table.

FCMAP—The Dell FCoE hardware accepts FCoE FLOGI from the ENode. The FCMAP determines which FCoE VLAN is accepted for the FCoE session.

NOTE

Only one FCoE VLAN is supported in the Fabric OS v6.3.1_cee release.

FCoE logout

The Dell FCoE hardware FCoE logout operates as follows:

ENodes can log out from the Dell FCoE hardware using the FCoE encapsulated, FC ELS frame. Dell FCoE hardware in the fabric updates the MAC address to WWN/PID mappings upon logout. The Dell FCoE hardware also handles scenarios of implicit logout where the ENode has left the fabric without explicitly logging out.

FCoE LOGO—The Dell FCoE hardware accepts the FCoE LOGO from the ENode. The FCoE LOGO ACC is sent to the ENode if the ENode MAC address matches the VN_port table on the Dell FCoE hardware. The LOGO is ignored (not rejected) if the ENode MAC address does not match. The ENode logout is updated in the VN_port table.

10

Dell Converged Enhanced Ethernet Administrator’s Guide

 

53-1002116-01

Page 28
Image 28
Dell 53-1002116-01 manual FIP logout, FCoE login, FCoE logout