type type—The sampling method for the selected variable and calculating the value to be compared against the thresholds. If the method is absolute, the value of the selected variable is compared directly with the thresholds at the end of the sampling interval. If the method is delta, the selected variable value at the last sample is subtracted from the current value, and the difference compared with the thresholds.

startup direction—The alarm that may be sent when this entry is first set to valid. If the first sample (after this entry becomes valid) is greater than or equal to the rthreshold, and direction is equal to rising or rising-falling, then a single rising alarm is generated. If the first sample (after this entry becomes valid) is less than or equal to the fthreshold, and direction is equal to falling or rising-falling, then a single falling alarm is generated.

owner name—Enter a name that specifies who configured this alarm. If unspecified, the name is an empty string.

Default Configuration

The following parameters have the following default values:

type type—If unspecified, the type is absolute.

startup direction—If unspecified, the startup direction is rising-falling.

Command Mode

Global Configuration mode

User Guidelines

There are no user guidelines for this command.

Example

The following example configures the following alarm conditions:

Alarm index—1000

Variable identifier—dell

Sample interval—360000 seconds

Rising threshold—1000000

Falling threshold—1000000

Rising threshold event index—10

Falling threshold event index—20

Console (config)# rmon alarm 1000 dell 360000 1000000 1000000 10 20

show rmon alarm-table

The show rmon alarm-tableUser EXEC mode command displays the alarms summary table.