3.Route the cable through the cable management loop and then to the FC-AL adapter card in slot 7.

4.Connect the free end of the FC-AL filer-to-PowerVault 700N storage system cable to the filer’s FC-AL adapter card connector in slot 7 (see Figure 2-9). Tighten the locking screws on the cable’s DB-9 connector.

In Figure 2-9, the first loop is connected to the FC-AL0 interface of an 760N. The second loop is connected to the FC-AL adapter in slot 7 on the 740N or 760N filer.

5.Connect successive PowerVault 700N storage systems by connecting short DB9-to-DB9 jumpers from the first PowerVault 700N storage system EXP con- nector to the next-higher (or next lower) PowerVault 700N storage system PRI connector installed in the rack. Repeat this for each PowerVault 700N storage system in each loop.

The configuration in Figure 2-9 has eight PowerVault 700N storage systems. Such a configuration must be installed in a rack, preferably with the filer located in the middle of the rack and four PowerVault 700N storage systems above and four below the filer. A rack is not shown in the illustration.

FC-AL1 loop

FC-AL0 loop

FC-AL adapter in slot 7

￿￿￿￿￿￿￿￿￿;￿￿￿￿$￿￿￿￿￿&'￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿:￿￿￿￿(￿￿￿￿￿$￿￿2￿￿￿￿￿.//￿￿

￿￿￿￿￿￿￿ 1￿￿￿-￿

The third FC-AL loop (loop 2) would be connected using this procedure, but using the FC-AL adapter card in slot 6 for the 740N filer, or using the FC-AL adapter card in slot 4 for the 760N filer.

Installing a Filer System 2-13

Page 43