Fans stopped; replace them!

This message appears if the fan assembly

 

of the filer stops functioning. Replace the

 

fan assembly as soon as possible.

 

 

Fault on shelf n

n—The PowerVault 700N storage system

 

enclosure address number. This message

 

appears when the system detects an error

 

on one or more Dell PowerVault 700N

 

storage systems. Check the LEDs of the

 

specified Dell PowerVault 700N storage

 

systems to see whether a fan or power

 

supply needs to be replaced. Replace the

 

faulty fan or power supply on the Dell

 

Power-Vault 700N storage system, if

 

needed.

 

 

Maintenance mode

The system is running in maintenance

 

mode. Refer to the Dell PowerVault 720N,

 

740N, and 760N System Administrator and

 

Command Reference Guide for more

 

information about maintenance mode.

 

 

Non Maskable interrupt

This message is usually generated by a

 

correctable (nonfatal) memory error, but

 

might signal other conditions.

 

If this message appears repeatedly, it

 

might indicate a defective memory mod-

 

ule (DIMM). Refer to the console

 

messages or to the /etc/messages file for

 

detailed information.

 

 

NFS service not enabled

This message appears only if you have

 

licensed NFS. NFS service has been dis-

 

abled either because the system failed to

 

enable it when it started, or because you

 

disabled it with the nfs off command.

 

 

Parity disk is broken

The parity disk is not operating and the

 

system is in degraded mode. The solution

 

depends on whether a hot spare is

 

installed in the system. Refer to the Dell

 

PowerVault 720N, 740N, and 760N System

 

Administrator and Command Reference

 

Guide for information about replacing a

 

faulty disk.

 

 

3-18 Dell PowerVault 720N, 740N, and 760N Installation and Troubleshooting Guide

Page 70
Image 70
Dell 740N, 760N manual Mode. Refer to the Dell PowerVault 720N