8￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿.￿￿￿￿￿￿

If a system problem has caused the system to halt or restart, the LCD displays one of the system halt messages listed in Table 3-11.

￿￿￿￿￿￿￿￿￿￿￿￿￿ 1￿￿￿-￿3￿￿￿￿#￿￿￿￿￿:￿￿￿￿￿￿￿

-￿￿￿￿￿￿￿￿￿￿￿￿￿

$￿￿￿￿￿￿￿￿￿￿

 

 

CPU fan has failed

The filer’s CPU fan has stopped function-

 

ing. The system automatically shuts down.

 

 

Dumping core

The system is dumping core after a sys-

 

tem crash.

 

For information about core files, refer to

 

the Dell PowerVault 720N, 740N, and 760N

 

System Administrator and Command Ref-

 

erence Guide .

 

 

Disk hung during swap!

A disk error occurred as you were hot

 

swapping a disk. To recover, disconnect

 

the Dell PowerVault 700N storage system

 

from the power supply and wait 15 sec-

 

onds to allow all disks to spin down.

 

Reconnect the power source to the Dell

 

PowerVault 700N storage system and

 

enter boot to restart the system.

 

 

Error dumping core

The system cannot dump core during a

 

system crash; the system restarts without

 

dumping core.

 

 

Halted

This message appears after you enter a

 

halt command or after the system is

 

halted automatically because of a prob-

 

lem. If an error message appears during

 

the restart, follow the instructions sug-

 

gested in this chapter to fix the problem.

 

 

ISA IOCHK

ISA bus failure.

 

 

Panicking

The system is crashing. If the system

 

does not hang while crashing, the mes-

 

sage, Dumping core, appears.

 

 

Rebooting

The system is restarting. The boot mes-

 

sages follow.

 

 

Replace NVRAM batteries!

Both NVRAM batteries are discharged.

 

The system automatically shuts down.

 

 

Troubleshooting the Filer Hardware 3-21

Page 73
Image 73
Dell 740N, 720N, 760N manual System Administrator and Command Ref