Table 3-9 lists LCD error messages that the system detects when starting.

￿￿￿￿￿￿￿￿;￿￿￿ ￿￿￿￿￿(￿#￿￿￿￿￿:￿￿￿￿￿￿￿

-￿￿￿￿￿￿￿￿￿￿￿￿￿

$￿￿￿￿￿￿￿￿￿￿

 

 

Add at least xMB more memory

x—The amount of memory you need to

 

add to the system. The system has too lit-

 

tle memory for the amount of disk space

 

installed.

 

 

Cannot initialize labels

When it tries to create a new file system,

 

the system cannot initialize the disk

 

labels.

 

 

Cannot read labels

This error occurs only when the filer tries

 

to initialize a new file system. The mes-

 

sage indicates that the filer has a problem

 

reading disk labels it wrote to the disks.

 

This error occurs because

￿

￿

The system fails to read the size of a disk.

The written disk labels were not valid.

Can’t open /etc/rc

The /etc/rc file is corrupted. Run setup by

 

entering setup at the hostname>

 

prompt.

 

The setup program prompts you to enter

 

the necessary system configuration infor-

 

mation. For more information about the

 

filer setup program, refer to the Dell

 

PowerVault 720N, 740N, and 760N System

 

Administrator and Command Reference

 

Guide.

 

 

Dirty shutdown in degraded

The file system might be inconsistent

mode

because you did not shut down the sys-

 

tem cleanly when it was in degraded

 

mode.

 

 

Configuration exceeds max PCI

Memory space for mapping in PCI cards

space

has been exhausted.

 

Make sure that all expansion cards in the

 

filer are supported cards.

 

 

Disk labels scrambled!

The disk labels are corrupted.

 

 

Troubleshooting the Filer Hardware 3-13

Page 65
Image 65
Dell 760N, 720N, 740N manual Administrator and Command Reference