$ | |
|
|
Parity disk x% rebuilt | The system shows the amount of com- |
| pleted data reconstruction on the spare |
| disk after the system entered degraded |
| mode. |
| |
| error occurs during reconstruction, the |
| error message overrides this message. |
|
|
Power supply degraded! | One of the power supply units is down. |
| For more information about this error |
| message, check the messages on the |
| console. The power supply unit (1 or 2) |
| generating the alarm is identified on the |
| console message. |
|
|
Replace NVRAM batteries! | This message appears in these situations: |
An NVRAM card battery is low or dis- charged. Replace both batteries as soon as possible.
Both batteries on the NVRAM card are low or discharged. The system will shut down every 24 hours to encourage you to replace the batter- ies as soon as possible. To set the time that the system runs before it automatically shuts down, use the raid.timeout option with the options command. Refer to the Dell PowerVault 720N, 740N, and 760N System Administrator and Command Reference Guide for more information.
Both NVRAM card batteries are low or discharged and the system is in degraded mode. The system shuts down immediately.