Operating Your Storage Enclosure

Before You Begin

Before connecting your storage enclosure, ensure that the following are available:

Power cables

SAS cables

Rail kit

Dell Systems Management Tools and Documentation media

Documentation

Getting Started Guide

Rack Installation Instructions

Safety instructions

Cabling Your Enclosure

You can cable your enclosure in either a unified-mode configuration or in a split-mode configuration.

In a unified-mode configuration your enclosure is connected to one host, for example, a server with a controller card. Your enclosure can be one of up to four enclosures daisy-chained to a single port on the controller card in your host server. The enclosure can also be connected in a redundant path mode with two connections to single host server. See Figure 2-2 and Figure 2-3 for cabling diagrams of a unified mode configuration.

In a split-mode configuration, your enclosure is connected to two separate controller cards. The controller cards may reside in the same server or in two different servers. The enclosure bus is logically split in half where the first half of the enclosure is managed by one controller and the second half of the enclosure is managed by the second controller. Table 2-1 lists the

Operating Your Storage Enclosure

19

Page 19
Image 19
Dell E03J Series, E04J001, E04J Series, E03J001 Operating Your Storage Enclosure, Before You Begin, Cabling Your Enclosure