drives that are controlled by each enclosure management module (EMM) in a
Table
Enclosure | EMM 0 | EMM 1 |
|
|
|
Dell PowerVault MD1200 | Drives 6 to 11 | Drives 0 to 5 |
Dell PowerVault MD1220 | Drives 12 to 23 | Drives 0 to 11 |
|
|
|
NOTE: Clustering is not supported on PowerVault MD1200 and
PowerVault M1220 enclosures.
The operating mode is selected using the enclosure mode switch on the front panel of the enclosure.
NOTE: The enclosure mode switch must be set to either unified mode or split mode before the enclosure is turned on. Changing the configuration mode after turning on the enclosure has no effect on the enclosure configuration until the enclosure
is rebooted.
Connecting the Enclosure
1Ensure that the latest version of Dell OpenManage™ Server Administrator is installed. For installation instructions and supported operating systems, see the Server Administrator documentation.
NOTE: The minimum version of Server Administrator supported on your enclosure is 6.2.
2Turn off the host system and all attached devices.
3Connect the SAS cable(s) to the EMM SAS connector on the storage enclosure and to the RAID controller on the host system. Push the cable into the connector until it clicks into place. See Figure
NOTE: Connectors on both ends of the SAS cable are universally keyed. You can connect either end of the cable to the EMM or the RAID controller.
NOTE: To remove the SAS cable, you must pull the
20
Operating Your Storage Enclosure