Delta 28-348 instruction manual Adjusting Table Stops, To adjust the 90 degree stop

Models: 28-348

1 28
Download 28 pages 45.95 Kb
Page 18
Image 18

ADJUSTING THE

TABLE STOPS

To adjust the 90 degree stop

1. DISCONNECT MACHINE FROM POWER SOURCE.

2.Loosen the table clamp handles (A) Fig. 43, and tilt the table to the right.

3.Rotate the stop (B) Fig. 45 out of the way.

4.Place a square (G) Fig. 46, on the table and set blade square to table.

5.Tighten table clamp handles (A) Fig. 43.

6.Rotate the stop (B) Fig. 45, until the tallest screw is under the table.

7.Turn the screw up or down until the screw touches the table skirt.

8.Loosen screw (K) Fig. 47 and move pointer (J) to the “0”, and tighten screw (K).

To set the adjustable stops:

The adjustable stops (quick stop table presets) can be used to set the table any where from 0 to 9 degrees left for beveling operations.

1. DISCONNECT MACHINE FROM POWER SOURCE.

2.Loosen the two clamp handles (A) Fig. 43.

3.Tilt the table to the right, and turn the stop until either stop screw (M) or (N) Fig. 48, is under the table skirt.

4.Tilt the table to the left until it rests on the selected stop screw (M) or (N) Fig. 48.

5.The angle can be set by turning the stop screw and checking the angle on the side of the scale with pointer

(J) Fig. 47.

6.Adjust the other stop screw (M) or (N) Fig. 48, in the same manner.

B

F

Fig. 45

G

Fig. 46

J

K

Fig. 47

M

N

Fig. 48

18

Page 18
Image 18
Delta 28-348 instruction manual Adjusting Table Stops, To adjust the 90 degree stop