DeviceNet Remote I/O Communication Module RTU-DNET

Attribute

Access

 

 

 

 

Name

Range

Default

Explanation

ID

rule

 

 

 

 

30

Get/Set

Start CR for

N/A

N/A

Start CR for the input data of special

module 6

module 6

 

 

input data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input data

 

 

Length of input data of special module

31

Get/Set

length for

N/A

N/A

6

 

 

module 6

 

 

 

 

 

 

 

 

 

 

 

 

 

32

Get/Set

Start CR for

N/A

N/A

Start CR for the input data of special

module 7

module 7

 

 

input data

 

 

 

 

 

 

 

 

 

 

 

 

 

33

Get/Set

Input data

N/A

N/A

Length of input data of special module

length for

7

 

 

module 7

 

 

 

 

 

 

 

 

 

 

 

 

 

34

Get/Set

Start CR for

N/A

N/A

Start CR for the input data of special

module 8

module 8

 

 

input data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input data

 

 

Length of input data of special module

35

Get/Set

length for

N/A

N/A

8

 

 

module 8

 

 

 

 

 

 

 

 

 

 

 

 

 

36 ~ 49

 

 

 

Reserved

 

 

 

 

 

 

 

50

Get/Set

Start CR for

N/A

N/A

Start CR for the output data of special

module 1

module 1

 

 

output data

 

 

 

 

 

 

 

 

 

 

 

 

 

51

Get/Set

Output data

N/A

N/A

Length of output data of special

length for

module 1

 

 

module 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start CR for

 

 

Start CR for the output data of special

52

Get/Set

module 2

N/A

N/A

module 2

 

 

output data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output data

 

 

Length of output data of special

53

Get/Set

length for

N/A

N/A

module 2

 

 

module 2

 

 

 

 

 

 

 

 

 

 

 

 

 

54

Get/Set

Start CR for

N/A

N/A

Start CR for the output data of special

module 3

module 3

 

 

output data

 

 

 

 

 

 

 

 

 

 

 

 

 

55

Get/Set

Output data

N/A

N/A

Length of output data of special

length for

module 3

 

 

module 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start CR for

 

 

Start CR for the output data of special

56

Get/Set

module 4

N/A

N/A

module 4

 

 

output data

 

 

 

 

 

 

 

 

 

 

 

 

 

57

Get/Set

Output data

N/A

N/A

Length of output data of special

length for

module 4

 

 

module 4

 

 

 

 

 

 

 

 

 

 

 

 

 

58

Get/Set

Start CR for

N/A

N/A

Start CR for the output data of special

module 5

module 5

 

 

output data

 

 

 

 

 

 

 

 

 

 

 

 

 

59

Get/Set

Output data

N/A

N/A

Length of output data of special

length for

module 5

 

 

module 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start CR for

 

 

Start CR for the output data of special

60

Get/Set

module 6

N/A

N/A

module 6

 

 

output data

 

 

 

 

 

 

 

 

 

 

 

 

 

DVP-PLC Application Manual

13

Page 15
Image 15
Delta Electronics manual DeviceNet Remote I/O Communication Module RTU-DNET