Delta Electronics manual How to Construct a DeviceNet Network Using RTU-DNET, Dvpdnet-Sl

Models: RTU-DNET

1 41
Download 41 pages 58.88 Kb
Page 24
Image 24

DeviceNet Remote I/O Communication Module RTU-DNET

5 How to Construct a DeviceNet Network Using RTU-DNET

In this section, we will explain how to configure RTU-DNET and the I/O mapping relation between RTU-DNET and DVPDNET-SL by an application example.

5.1How to Construct DeviceNet by RTU-DNET

1.The DeviceNet network

DVPDNET-SL

DVP28SV

DVPDNETDVP28SV

DeviceNet

network configuration tool

RUN

STOP

Master

TE

ND

U-

TR

DeviceNet

VD P- 80 TS

DVP-16SP

DA4 0-P VD

CT4 0-P VD

TP4 0-P DV

DVP-02DA

2.

Set up DVPDNET-SL and RTU-DNET according to the table below.

 

 

 

 

 

 

 

 

 

 

 

Module

Node address

 

Baud rate

 

 

 

DVPDNET-SL

1

 

500 kbps

 

 

 

RTU-DNET

2

 

500 kbps

 

3.

Pleae check if all Slim DI/DO extension units, special modules and RTU-DNET are working normally, if the

 

wiring of the entire network is correct, and if the power supply in DeviceNet is normal.

5.2 How to Configure Network by DeviceNet Network Configuration Tool

 

 

1.

Configuration of RTU-DNET

 

 

 

 

 

(1) Open DeviceNetBuilder software, as below:

 

 

22

DVP-PLC Application Manual

Page 24
Image 24
Delta Electronics manual How to Construct a DeviceNet Network Using RTU-DNET, Dvpdnet-Sl