Delta Electronics manual DeviceNet Remote I/O Communication Module RTU-DNET

Models: RTU-DNET

1 41
Download 41 pages 58.88 Kb
Page 29
Image 29

DeviceNet Remote I/O Communication Module RTU-DNET

Item

Function

Default

IO Module

How RTU-DNET will react when it detects errors. You can

Alarm

Error Treatment

choose “Ignored”, “Alarm” or “Stop DeviceNet IO”.

 

 

For you to decide whether to add control word and status

 

Add control word

word to I/O data. When you choose not to do it, the I/O data

 

in RTU-DNET and DeviceNet master will not include control

 

and status word to

Not to add

IO data

word and status word. If you choose to add them in, the I/O

 

data in RTU-DNET and DeviceNet master will include

 

 

 

 

control word and status word.

 

(14)Confirm all the configurations are correct and click on “Download” to download the configuration to RTU-DNET. After the download is completed, click on “OK".

2.Configuration of DVPDNET-SL

(1)Double click on DNET Scanner (node 01), and the “Scan Module Configuration…” dialog box will appear. You can find the currently available node, RTU-DNET, in the list on the left side. On the right side, there is an empty “Scan List”.

(2) Move the slave devices on DeviceNet in the “Available Nodes” list on the left side to the “Scan List” on the right side. Select a node and click on > . Follow the steps to move all the nodes to the scan list.

DVP-PLC Application Manual

27

Page 29
Image 29