Desa V)CD36RN, (V)CD36RPE Operating Fireplace, Millivolt For your safety Read before lighting

Models: V)CD36RN (V)CD36TN (V)CD36RPE (V)CD36RNE (V)CD36RP (V)CD36TNE (V)CD36TP (V)CD36TPE

1 52
Download 52 pages 28.86 Kb
Page 31
Image 31

Fireplace

Installation

Continued

WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken.

4.Open the bag of ember materials.

5.Break apart about quarter sized pieces and place about a single layer along the full length of the ember tray to hide the bottom edge of the base log. (see Figure 59).

6.Replace the glass door and louver panels. See

Removing/Replacing Glass Door, page 29.

Ember

Material

Ember

Tray

Figure 59 - Applying Ember Material

Operating Fireplace

Millivolt

for your safety

Read before lighting

WARNING: If you do not fol- low these instructions exactly,

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician.

Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

lighting

instructions

1.STOP! Read the safety information above.

2.Open lower louver panel.

3.Turn off all electric power to the fire- place.

4.Push in gas control knob slightly and turn clockwise to “OFF” (see Figure 60).

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the safety information above. If you don’t smell gas go to the next step.

6.The pilot is located by the main burner and should not require accessing for lighting.

7.Turn gas control knob counterclockwise to “PILOT”.

a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

Gas Control Variable

Knob

Control Knob

 

OT

 

IL

 

P

 

IL

P OT

F

HI

F

O

O

 

N

 

LO

IN

OUT

Piezo Ignitor

TPTH TP TH

Figure 60 - Control Valve

116035-01E

www.desatech.com

31

Page 31
Image 31
Desa V)CD36RN, (V)CD36RPE Operating Fireplace, Millivolt For your safety Read before lighting, Lighting Instructions

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.