TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

When ignitor button is pressed,

1. Gas supply turned off or equip-

1.

Turn on gas supply or open

there is spark at pilot but no

 

ment shutoff valve closed

2.

equipment shutoff valve

ignition

2. Gas control knob not in PI-

Turn gas control knob to PILOT

 

3.

LOT position

3.

position

 

Gas control knob not pressed

Press in gas control knob while

 

4.

in while in PILOT position

4.

in PILOT position

 

Air in gas lines when in-

Continue holding down con-

 

 

stalled

 

trol knob. Repeat igniting

 

5. Depleted gas supply (propane/

 

operation until air is removed

 

5. Contact local propane/LP gas

 

6.

LP models only)

6.

company

 

Pilot is clogged

Clean pilot (see Cleaning and

 

 

 

 

Maintenance, page 37) or re-

 

7.

Gas regulator setting is not

7.

place pilot assembly

 

Replace gas regulator

 

 

correct

 

 

 

Pilot lights but flame goes out

1. Gas control knob not fully

1.

Press in gas control knob

when control knob is released

2.

pressed in

2.

fully

 

Gas control knob not pressed

After pilot lights, keep gas

 

 

in long enough

 

control knob pressed in 30

 

3.

Equipment shutoff valve not

3.

seconds

 

Fully open equipment shutoff

 

4.

fully open

4.

valve

 

Pilot flame not touching

A) Contact local natural or

 

 

thermocouple, which allows

 

propane/LP gas company

 

 

thermocouple to cool, caus-

 

B) Clean pilot (see Cleaning

 

 

ing pilot flame to go out. This

 

and Maintenance, page 37)

 

 

problem could be caused by

 

or replace pilot assembly

 

 

one or both of the following:

 

 

 

 

 

A) Low gas pressure

 

 

 

 

 

B) Dirty or partially clogged

 

 

 

 

5.

pilot

5.

Hand tighten until snug, then

 

Thermocouple connection

 

6.

loose at control valve

6.

tighten 1/4 turn more

 

Thermocouple damaged

Replace pilot assembly

 

7.

Control valve damaged

7.

Replace control valve

 

 

 

 

 

Burner does not light after pilot

1. Burner orifice clogged

1.

Clean burner (see Cleaning

is lit

 

 

 

and Maintenance, page 37) or

 

2.

Inlet gas pressure is too low

2.

replace burner orifice

 

Contact local propane/LP or

 

3.

Thermopile leads disconnect-

3.

natural gas company

 

Reconnect leads to TP & TPTH

 

4.

ed or improperly connected

4.

terminals on control valve

 

Thermopile is defective

Replace thermopile

 

 

 

 

 

Delayed ignition burner

1. Manifold pressure is too low

1.

Contact local propane/LP or

 

2.

Burner porting or orifice

2.

natural gas company

 

Clean burner (see Cleaning

 

 

clogged

 

and Maintenance, page 37) or

 

 

 

 

replace burner orifice

 

116035-01E

www.desatech.com

39

Page 39
Image 39
Desa V)CD36RN When ignitor button is pressed, Turn on gas supply or open, LOT position Position, Seconds, Low gas pressure

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.