Desa (V)CD36TPE, (V)CD36RPE Replacement Parts, Service Hints, Technical Service, Specifications

Models: V)CD36RN (V)CD36TN (V)CD36RPE (V)CD36RNE (V)CD36RP (V)CD36TNE (V)CD36TP (V)CD36TPE

1 52
Download 52 pages 28.86 Kb
Page 44
Image 44

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA’s Customer Service Department at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your fireplace

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA at 1-866-672-6040 for referral infor- mation.

When calling DESA, have ready

model number of your fireplace

the replacement part number

Service Hints

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply might be low (propane/ LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

Technical Service

You may have further questions about installation, operation or troubleshooting. If so, contact DESA’s Customer Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

YoucanalsovisitDESA’stechnicalservicewebsiteat www.desatech.com.

Specifications

(V)CD36RN and (V)CD36TN

• Rating: 15,000/21,000 Btu/hr

• Gas Type: Natural Gas Only

• Ignition: Millivolt

• Manifold Pressure: below 2000 ft. elevation - 3.5" w.c. (0.87 kPa), above 2000 ft. elev. - 3.8" (0.94 kPa)

• Orifice Size (Main Burner): #44 DMS (0.086")

• Minimum Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)

• Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)

(V)CD36RP and (V)CD36TP

• Rating: 13,000/20,000 Btu/hr

• Gas Type: Propane/LP Gas Only

• Ignition: Millivolt

• Manifold Pressure: 10.0" w.c. (2.5 kPa)

• Orifice Size (Main Burner): #55 DMS (0.052")

• Minimum Inlet Supply Pressure: 11.0" w.c. (2.7 kPa)

• Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)

(V)CD36RNE and (V)CD36TNE

• Rating: 21,000 Btu/hr

• Gas Type: Natural Gas Only

• Ignition: Electronic

• Manifold Pressure: below 2000 ft. elevation - 3.5" w.c. (0.87 kPa), above 2000 ft. elev. - 3.8" (0.94 kPa)

• Orifice Size (Main Burner): #44 DMS (0.086")

• Minimum Inlet Supply Pressure: 5.5" w.c. (1.1 kPa)

• Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)

(V)CD36RPE and (V)CD36TPE

• Rating: 20,000 Btu/hr

• Gas Type: Propane/LP Gas Only

• Ignition: Electronic

• Manifold Pressure: 10.0" w.c. (2.5 kPa)

• Orifice Size (Main Burner): #55 DMS (0.052")

• Minimum Inlet Supply Pressure: 11.0" w.c. (2.7 kPa)

• Firebox Dimensions (HxWxD) (Flanges and Standoffs Not Included in Measurement): 35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)

44

www.desatech.com

116035-01E

Page 44
Image 44
Desa (V)CD36TPE, (V)CD36RPE, (V)CD36TNE, (V)CD36RNE Replacement Parts, Service Hints, Technical Service, Specifications

V)CD36RN, (V)CD36TN, (V)CD36RPE, (V)CD36RNE, (V)CD36RP specifications

The Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE represent a series of cutting-edge heating solutions designed to meet the diverse needs of modern users. These models stand out for their efficiency, user-friendly features, and advanced technologies that ensure optimal performance and comfort.

One of the main features of these Desa models is their impressive heating capacity. Each unit provides a reliable source of warmth, making them suitable for various environments, from residential homes to larger commercial spaces. The versatility of these models ensures that they can accommodate different room sizes and heating requirements effortlessly.

The Desa models incorporate advanced heating technologies, including efficient radiant heating systems. This technology allows for quicker heat distribution and a more comfortable ambient temperature. Users can enjoy the benefits of even heat coverage, eliminating cold spots and ensuring a pleasant living or working environment.

Energy efficiency is another critical characteristic of the Desa models. Designed with modern energy-saving features, these units help reduce energy consumption while maintaining powerful heating capabilities. This aspect not only leads to cost savings on energy bills but also contributes to a more sustainable approach to heating.

Convenience is paramount in the design of the (V)CD36 series. Many of these models come equipped with programmable thermostats and remote control options, enabling users to set their desired heating schedule with ease. This flexibility allows for personalized comfort and lets users maintain their preferred temperatures without unnecessary manual adjustments.

Safety features are also a top priority in the (V)CD36 series. Each model is equipped with essential safety mechanisms, including automatic shut-off systems and tip-over protection, ensuring peace of mind when the units are in operation.

The aesthetic design of the Desa (V)CD36 series complements various interior styles. With sleek finishes and a modern silhouette, these heating solutions blend seamlessly into any décor while providing essential functionality.

In summary, the Desa (V)CD36TPE, (V)CD36TP, (V)CD36TNE, (V)CD36RP, and (V)CD36RNE models exemplify innovation in heating technology, offering energy efficiency, safety, and user convenience. These features make them an excellent choice for anyone seeking reliable and effective heating solutions.