Desa (V)CD36TN, (V)CD36TP Vertical Termination Configurations for Top Vent, High Wind Termination

Models: V)CD36RN (V)CD36TN (V)CD36RPE (V)CD36RNE (V)CD36RP (V)CD36TNE (V)CD36TP (V)CD36TPE

1 52
Download 52 pages 28.86 Kb
Page 19
Image 19

Venting Installation

instructions

Continued

Vertical Termination Configurations for

Top Vent

Figures 30 and 33 show four different configura- tions for vertical termination.

VERTICAL VENT INSTALLATIONS USING MULTIPLE 90° ELBOWS (V)CD36T TOP VENT

Note: Install a

VR-58 vertical restrictor ring into inner pipe

section prior to

attaching vent

termination cap.

90° Elbow

Venting with Three 90° Elbows

 

Horizontal (H1) +

Vertical (V)

Horizontal (H2)

8' Min.

5' Max

10' Min.

8' Max

12' Min.

11' Max

14' Min.

14' Max

16' Min.

17' Max

18' Min.

20' Max

40' Min.

20' Max

Figure 30 - Vertical Venting

Configuration using Three 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination)

Venting with Two 90° Elbows

Vertical (V)

Horizontal (H)

8' Min.

6' Max

9' Min.

8' Max

10' Min.

10' Max

12' Min.

14' Max

14' Min.

18' Max

40' Min.

20' Max

90° Elbow

Note: Install a

 

VR-58 vertical

 

restrictor ring

 

into inner pipe

 

section prior to

 

attaching vent

 

termination

 

cap.

Figure 31 - Vertical Venting Configuration Using Two 90° Elbows (Model (V)CD36T with Vertical Round

High Wind Termination)

 

Venting with Two 90°

 

Elbows

 

Vertical

Horizontal

 

(V1)

(H)

 

8' Min.

9' Max

 

9' Min.

11' Max

 

10' Min.

13' Max

 

12' Min.

17' Max

 

14' Min.

20' Max

 

Note: Install a

 

VR-58 vertical

 

restrictor ring

 

into inner pipe

 

section prior to

 

attaching vent

90° Elbow

termination

cap.

 

Note: Vertical (V1) + Vertical (V2) = 40' Max. Max. Horizontal Above 14' Vertical = 20'

Figure 32 - Vertical Venting

Configuration Using Two 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination)

116035-01E