6.Wait five (5) minutes to clear out any gas.

Then smell for.

gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety infor- mation above. If you don’t smell gas go to the next step.

7.Turn equipment shutoff valve counterclock- wise to the ON position. Do not force.

8.Close lower louver panel.

9.Turn on all electric power to the fireplace.

10.Turn the wall switch to the ON position.

11.Visually locate the pilot. The ignitor should begin to spark and

the main burner should ignite once flame appears at pilot.

If lighting the appliance for the first time each season, it may take several attemps before the supply gas can reach the pilot and main burner.

If the appliance will not stay lit after sev- eral attempts, follow the instructions To Turn Off Gas To Appliance, below, and call your service technician or gas supplier.

NOTICE: During initial operation of a new heater, the burning of residues from the manufacturing process of the firebox and logs willproduceapaper-burningsmell andorangeflames.Openawindow forthefirst fewhoursofoperation to adequately vent this smell.

Figure 64 - Pilot

TO TURN OFF GAS

TO APPLIANCE

1.Turn off the wall switch.

2.Turn off all electric power to the appliance if service is to be performed.

3.Open lower louver panel.

4.Turn equipment shutoff valve clockwise to OFF. Do not force.

5.Close lower louver panel.

Optional Wireless

Remote Operation

Note: The WRC receiver and hand-held remote control kit must be purchased separately (see Accessories, page 45). Follow installation in- structions included with the remote control.

1.Turn equipment shutoff valve to ON posi- tion. You can now turn the burner on and off with the hand-held remote unit.

IMPORTANT: Be sure to press the ON/OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

2.Press the ON/OFF button to turn the burner on and off.

IMPORTANT: Do not leave the selectorswitch inthe REMOTE or ON position when the pilot is not lit. This will drain the battery.

operating optional

GWMT1 - Wall Mounted

Thermostat

WARNING: Do not con- nect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

Light the fireplace as instructed in Lighting Instructions on page 34. Set wall thermostat to desired temperature.

This thermostat has been electronically cali- brated at the factory and requires no adjust- ment or leveling.

Upon installation, the thermostat must be al- lowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. To turn the fireplace off, adjust thermostat to the lowest setting and turn the gas control knob back to PILOT. The pilot will remain lit.

IMPORTANT: To turn the pilot off, turn the gas control knob on the heater to the OFF position.

operating optional blower accessory

Locate the blower controls by opening the lower louver panel on the fireplace. Blower controls are located on the right side of the switch bracket to the left just inside the louver panel. The BK manual blower and the BKT thermo- statically-controlled blower have an ON setting and an OFF setting. The blower will only run when the switch is in the ON position. In the OFF position, the blower will not operate.

116035-01E

www.desatech.com

35

Page 35
Image 35
Desa (V)CD36RPE, (V)CD36TNE, (V)CD36TPE, (V)CD36RNE installation manual Optional Wireless Remote Operation, Pilot