32

Wah Min/Max

You can set the Wah effect’s minimum and maximum values with the Expression row. To do so,
follow these steps:
Press the 1. Edit button until the Expression row is selected (indicated by the LED lighting on
the Expression row).
Rotate
2. Knob 1 to select .
Rotate 3. Knob 3 to adjust the Wah effect’s minimum value.
Rotate 4. Knob 4 to adjust the Wah effect’s maximum value.

Expression Update

You can set up the RP1000’s Expression pedal to update its position each time you change
presets. Normally, the Expression pedal only updates its position on a preset change when it’s
linked to the Volume Pre or Volume Post parameter in a preset. This lets the Expression pedal
behave like a real volume pedal between preset changes. When Expression Update is enabled
(ON), the Expression pedal will update its position no matter what parameter it’s linked to, so it
has more of an “analog” feel like a typical standalone expression pedal.
To enable the Expression Update function, follow these steps:
Press the 1. Edit button until the Expression row is selected (indicated by the LED lighting on
the Expression row).
Rotate
2. Knob 1 to select . The default setting is for Expression Update is .
Press 3. Knob 1 to enable or disable Expression Update.
Expression Update affects all presets. You don’t have to save this change to each preset.

Factory Reset

This function resets the RP1000 to its original factory settings. This procedure erases all custom
User presets, and recalibrates the Expression Pedal.
ATTENTION: Performing this function will erase all user-programmed data. All
such data will be lost forever! Be sure you want to erase the memory and start
fresh before continuing with this procedure.
The procedure for performing a Factory Reset is as follows:
Press and hold the
1. Store button while powering up the RP1000.
When the display prompts you with 2. , release the Store button, which is now
flashing.
Press and hold the flashing 3. Store button for 3 seconds until  appears in the
display and release. The Restore procedure takes several seconds to complete; during the
procedure, the display will count up. After the Restore procedure is complete, the Expres-
sion Pedal calibration procedure will begin.

Expression Pedal Calibration

The Expression Pedal on the RP1000 needs to be recalibrated for use after you do a factory
reset. This calibration procedure automatically starts after the factory reset procedure is com-
pleted. (You can also start the calibration procedure by pressing and holding the currently active
preset’s footswitch for about 5 seconds.) If the pedal’s calibration fails, or if the pedal does not
function properly, it can be re-calibrated using the calibration procedure. This will not erase the
User presets. The procedure for calibrating the expression pedal is as follows:
Press and hold the currently active preset’s footswitch until
1.  appears in the
display (, , and  will be displayed before  is accessed, after
about 5 seconds.)
When the Display prompts you with
2. , rock the Expression Pedal forward (toe
down) and press Footswitch 5.