DolbyRemote Installation and Operation

Establishing Communication

 

 

 

 

through the front panel of the encoder. The rate you select in DolbyRemote must match the rate selected in the unit.

Address

The default address setting for the DP567 and DP569 is 0x8280. If the address has been changed from the front panel of the encoder, set the remote address accordingly. If DP561 is selected as the Device Type, only the Port parameter may be set; Baud and Address are fixed at 38,400 and 9080, respectively.

2.1.3Off-Line

The DolbyRemote application may be used off line, without the presence of an encoder. This allows configurations to be preprogrammed and stored. Off-line mode is selected by checking the Off Line box when opening a unit.

Figure 2-2Device Off Line

Once the desired parameters have been set, as described above, click OK. The DolbyRemote Window is displayed. When the DolbyRemote application establishes communication with the unit, it will display the unit's current settings.