DolbyRemote Installation and Operation

Introduction

 

 

 

 

Microsoft DLL Files

If you have an older version of Windows® 95, you may see an error message about Oleaut32.dll when you launch DolbyRemote. If this occurs, download and install the Windows Library Update from Microsoft (www.microsoft.com/windows95/downloads).

1.5Cable Installation

There are two types of serial interface used on Dolby products, RS-232 and RS- 485. It is important to use the correct type of interface and the correct cable to ensure a reliable connection.

Each RS-232 port on a PC must be connected to a single device, however, the application can control many RS-232 ports. For example, with five free RS-232 ports on a computer, five devices may be controlled with a single instance of the DolbyRemote application.

A single RS-485 computer port may connect to several devices, provided the devices all have an RS-485 connection.

DolbyRemote is shipped with a cable for RS-232 connection between a PC and the front panel of a DP567/DP569 encoder. Connection to a PC RS-232 communications port is made with the D-9 end of the cable. The other end of the cable connects to the Remote port on the front panel of the encoder. Additional cables may be purchased from Dolby Laboratories.

RS-485 connection for the DP567/DP569 requires a separate cable, not provided. This connects to the rear panel serial port of the unit. Consult the product's users manual for RS-485 support information.

Connection between a PC and a DP561 encoder requires a standard null modem cable. The DP561 has only an RS-232 connection.

1-3

Page 9
Image 9
Dolby Laboratories P/N 91659 manual Cable Installation, Microsoft DLL Files