DolbyRemote Installation and Operation

Dolby Digital Parameters

 

 

 

 

4.5Input and Output Settings

Figure 4-6Input/Output Tab

4.5.1Input

Lock Status

Lock Status shows whether the input channels for the current coding mode have been detected and locked by the encoder.

Sample Rate

Sample Rate shows the sample rate of the digital input channels.

Integrity

Integrity shows the data integrity of the digital input channels.

Format

Format is a control parameter that allows you to choose the format of the data received from the input source. Available Input Format selections are:

PCM: Dolby Digital encoding will be enabled. When analog is selected as the DP567 input source, the input format must always be PCM.

Pre-encoded: Pass-through mode will be enabled. Pre-encoded bitstreams move through the unit, unmodified, to the output.

4-11

Page 27
Image 27
Dolby Laboratories P/N 91659 manual Input and Output Settings